Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)
Input alignment information:
Query sequence
MRVNITLEHKESGERLYLTSKNKRNTPDRLQLKKYSPKLRKHVVFTEVK
3W0F Chain:A ((273-282))
--------------------------------TYFCPHCQKH-------
General information:
TITO was launched using:
RESULT:
Template:
3W0F.pdb
Alignment :
align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) 1775 for 25 contacts (71.0/contact) +
2D Compatibility (PS) -1025 + (NN) -740 + (LL) 3044
1D Compatibility (HY) -800 + (ID) 150
Total energy: 2104.0 ( 84.16 by residue)
QMean score : 0.611
(partial model without unconserved sides chains):
PDB file :
Tito_3W0F.pdb
:
(Unconserved sides chains are recalculated) :
Sequence:
align-3W0F-query.scw
PDB file :
Tito_Scwrl_3W0F.pdb
: