Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)



Input alignment information:
Query sequenceMKIGIIGATGRAGSRILEEAKNRGHEVTAIVRNAGKITQTHKDINILQKDI--FDLTLSDLSDQNVVVDAYGVSPDEAEKHVTSLDHLISVLNGTVSP---RLLVVGGAASLQIDEDGNTLLESKGLREAPYYPTARAQAKQLEHLRSHQAEFSWTYISPSAMFEPGERTGDYQIGKDHLLFGSDGNSFISMEDYAIAVLDEIERPNHLNERFTVAGK
3DHN Chain:A ((6-218))-KIVLIGASGFVGSALLNEALNRGFEVTAVVRHPEKIKIENEHLKVKKADVSSLDEVCEVCKGADAVISAFNP------IYDETIKVYLTIIDGVKKAGVNRFLMVGGAGSLFI-APGLRLMDSGEVPEN-ILPGVKALGEFYLNFLMKEKEIDWVFFSPAADMRPGVRTGRYRLGKDDMIVDIVGNSHISVEDYAAAMIDELEHPKHHQERFTIG--


General information:
TITO was launched using:
RESULT:

Template: 3DHN.pdb
Alignment : align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) -20761 for 1475 contacts (-14.1/contact) +
2D Compatibility (PS) -19937 + (NN) 1617 + (LL) 304
1D Compatibility (HY) -2400 + (ID) 1700
Total energy: -42877.0 ( -29.07 by residue)
QMean score : 0.249

(partial model without unconserved sides chains):
PDB file : Tito_3DHN.pdb:





(Unconserved sides chains are recalculated) :
Sequence: align-3DHN-query.scw
PDB file : Tito_Scwrl_3DHN.pdb: