Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)



Input alignment information:
Query sequenceQQPSCAAQLTQLAPCARVGVAPAPGQPLPAPPAECCSALGAVSHD----CACGTLD------IINSLP---AKCG--LPR-VTCH--
1HYP Chain:? ((6-80))--PSC----PDLSIC----LNILGGSLGTV--DDCCALIGGLGDIEAIVCLCIQLRALGILNLNRNLQLILNSCGRSYPSNATCPRT


General information:
TITO was launched using:
RESULT:

Template: 1HYP.pdb
Alignment : align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) -32005 for 317 contacts (-101.0/contact) +
2D Compatibility (PS) -5907 + (NN) -4261 + (LL) 808
1D Compatibility (HY) -5200 + (ID) 900
Total energy: -47465.0 ( -149.73 by residue)
QMean score : 0.328

(partial model without unconserved sides chains):
PDB file : Tito_1HYP.pdb:





(Unconserved sides chains are recalculated) :
Sequence: align-1HYP-query.scw
PDB file : Tito_Scwrl_1HYP.pdb: