Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)



Input alignment information:
Query sequenceMAIIFAKEDDLE-EIISSHPKILLNFWAEWCAPCRCFWPTLEQFAEMEEGNVQVVKINVDKQRALAQKFDVKGIPNSLVLVDGEIKGAIAGIVSCDELRSRFKSLAK
2EIQ Chain:A ((4-100))--IIHLTDDSFDTDVLKADGAILVDFWAEWCGPCKMIAPILDEIADEYQGKLTVAKLNIDQNPGTAPKYGIRGIPTLLLFKNGEVAACKVGALSKGQLK--------


General information:
TITO was launched using:
RESULT:

Template: 2EIQ.pdb
Alignment : align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) -68089 for 683 contacts (-99.7/contact) +
2D Compatibility (PS) -10341 + (NN) -1280 + (LL) 976
1D Compatibility (HY) -8400 + (ID) 1600
Total energy: -88734.0 ( -129.92 by residue)
QMean score : 0.543

(partial model without unconserved sides chains):
PDB file : Tito_2EIQ.pdb:





(Unconserved sides chains are recalculated) :
Sequence: align-2EIQ-query.scw
PDB file : Tito_Scwrl_2EIQ.pdb: