Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)



Input alignment information:
Query sequenceMTKLKVTGLKKSFGANEVLKGIDIEVKEGEVVCVIGPSGSGKSTFLRCMNNLEEITAGEVVVDDFNITDKKVDINKVRENIGMVFQHFNLFPHLSVLENITLAPVELKKMDKEAAKSNALRLLEQVGLREKAEEFPNQLSGGQKQRVAIARALAMDPDIMLFDEPTSALDPEMVGEVLGVMKELAKGGMTMMIVTHEMGFAREVGDRVIFMDGGYIVEEGKPADIFDNPTNERTISFLDKVL
2Q0H Chain:A ((25-263))---IDVHQLKKSFGSLEVLKGINVHIREGEVVVVIGPSGSGKSTFLRCLNLLEDFDEGEIIIDGINLKAKDTNLNKVREEVGMVFQRFNLFPHMTVLNNITLAPMKVRKWPREKAEAKAMELLDKVGLKDKAHAYPDSLSGGQAQRVAIARALAMEPKIMLFDEPTSALDPEMVGEVLSVMKQLANEGMTMVVVTHEMGFAREVGDRVLFMDGGYIIEEGKPEDLFDRPQHERTKAFLSKVF


General information:
TITO was launched using:
RESULT:

Template: 2Q0H.pdb
Alignment : align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) -150161 for 1967 contacts (-76.3/contact) +
2D Compatibility (PS) -26280 + (NN) -13553 + (LL) 324
1D Compatibility (HY) -33600 + (ID) 8050
Total energy: -231320.0 ( -117.60 by residue)
QMean score : 0.597

(partial model without unconserved sides chains):
PDB file : Tito_2Q0H.pdb:





(Unconserved sides chains are recalculated) :
Sequence: align-2Q0H-query.scw
PDB file : Tito_Scwrl_2Q0H.pdb: