Modeling by threading (Tito software)
Unconserved sides chains calculation (Scwrl software)
Evaluation (QMean software)



Input alignment information:
Query sequenceMVKQLNSVEAFREFIHQYPLAVVHVMRDQCSVCHAVLPQIEDLMQSYPNVPLAVINQSQVEAIAGELNIFTVPVDLIFMNGKEMHRQGRFIDMQRFEHHLKQMNDSVNNDVDEHEYRK
3HHV Chain:A ((33-133))-VKHLNS-KNFDEFITKNKIVVVDFWAEWCAPCLILAPVIEELANDYPQVAFGKLNTEESQDIAMRYGIMSLPTIMFFKNGELVDQILGAVPREEIEVRLKSL---------------


General information:
TITO was launched using:
RESULT:

Template: 3HHV.pdb
Alignment : align.pir
Tito was launched with SMD and SCWRL
Tito text output
3D Compatibility (PKB) -102528 for 743 contacts (-138.0/contact) +
2D Compatibility (PS) -11093 + (NN) -4870 + (LL) 796
1D Compatibility (HY) -8800 + (ID) 1550
Total energy: -128045.0 ( -172.34 by residue)
QMean score : 0.658

(partial model without unconserved sides chains):
PDB file : Tito_3HHV.pdb:





(Unconserved sides chains are recalculated) :
Sequence: align-3HHV-query.scw
PDB file : Tito_Scwrl_3HHV.pdb: